Is This the Job You Need?
Say what the stove, insert or fireplace burns and what it is doing wrong. A crew member calls back to set a time.
What the Crew Does
Old clay flue tiles crack in a chimney fire or a quake, and a flue built for an open hearth is usually too wide for a stove's exhaust. Smoke cools in an oversized flue, draws poorly and leaves tar. A stainless liner matched to the stove outlet fixes both problems. We measure the outlet and the flue height, choose rigid or flexible pipe, add insulation where the gap to framing is tight, and finish the top with a cap.
Why a Stove Wants Its Own Flue
A masonry chimney built for an open fireplace usually has a big flue, sized to carry the large volume of smoke and air that an open fire sends up. A modern wood stove or insert sends far less, and it sends it through a small outlet. Put that small, hot exhaust into a big clay flue and it slows down, spreads out and cools, and cool smoke drops its tar on the walls. That is why stoves vented into an old, oversized flue often draft badly, smoke on start-up and build creosote faster than they should. A stainless liner sized to the stove's outlet keeps the exhaust moving fast and hot from the stove to the top of the chimney. The stove lights more easily, burns more cleanly and fouls its flue less. For a household that burns every night, that difference shows up in sweep bills, in wood use, and in how much the house smells of smoke.
Damage is the second reason stove owners reline. Old clay tile splits over decades, after a flue fire, or when a quake shakes the stack, and the cracks are often invisible from the fireplace. A Level 2 camera scan shows them. When the tile is cracked, smoke and heat can reach the brick and, through the brick, the wood framing around the chimney. Relining is usually the fix that makes a cracked flue safe to burn in without rebuilding the chimney, and it is the standard way to vent a new stove or insert into an old chimney. Pellet stoves and gas inserts need liners too, sized and rated for their exhaust; a pellet vent is pushed by a fan and must be sealed along its length. We size the liner to the appliance the maker specifies, not to the flue, because the stove sets the draft it needs.
From Measuring to the First Fire
A liner job starts with measurements: the height of the chimney from the stove or firebox to the top, the inside size of the flue and any offsets in it, the outlet of the appliance and the space around it. If the flue has a bend or a narrowing, we say whether the liner can pass or whether some old tile has to be chipped away first. On chimneys built on an outside wall, or where the space between the flue and the framing is tight, we fit an insulated liner, which keeps the exhaust hot on cold nights and keeps heat away from the framing. At the bottom the liner is joined to the stove or insert with the right fittings, and up top a plate seals the gap between liner and tile before the new cap is fitted. Then the stove gets its first fire on the new liner while we are there to see it draw.
The written quote lays out the liner type and size, whether it is insulated, the fittings at each end, any tile that has to be removed, the cap and the price. Liner work often goes together with an insert install, a new stove or a chimney repair, and when it does, each part gets its own line on one quote, which makes it easy to stage the work over two seasons if that suits you better. Fit the liner in the dry months if you can, so the stove is ready when the cold arrives; a liner on a stove you burn daily is worth having in place before the first cold week. Once it is in, a liner still needs sweeping, but it is a quicker and cleaner job than sweeping cracked clay. To start, use the contact page and describe today's stove or fireplace, the appliance you want next, and say if the stack runs through the house or up an exterior wall.
How Covington Chimney Services Works a Job
Fault Found First
We trace the problem before any part is ordered
Burners Know Burners
Woodstoves, pellet units and open hearths are our daily work
Price on Paper
You see the figure in writing before work starts
Test Fire Together
After a stove fix, the first fire is built while you watch
Chimney Liner Installation around the region
Pick your town for notes on how local weather and housing shape this job there.
Nothing turned up for that spelling. The town next door may cover your street.
Other Jobs We Take On
Chimney Sweep
Creosote scraped and brushed off the flue walls, bagged and hauled off, before the woodpile comes indoors.
Open →Chimney Inspection
An NFPA 211 Level 1 or Level 2 look at the stove, flue, crown and cap, with findings written in plain order.
Open →Chimney Repair
Cracked crowns, open joints and loose brick above a working stove put right before they let water or heat through.
Open →Fireplace Inspection
Open hearth, firebox walls, damper and hearth extension looked over before the season's first log goes in.
Open →Fireplace Repair
Cracked firebrick, crumbling joints and a sticking damper fixed so the open hearth burns safely again.
Open →Chimney Level 2 Inspection
A recorded camera pass through the full flue plus attic and crawl space checks, for sales, stove swaps or after a flue fire.
Open →Chimney Cap Installation
A steel cap with a tight spark screen, stopping rain, birds and the embers a hard-burning stove throws off.
Open →Chimney Flashing Repair
Metal at the roof-to-chimney joint resealed or renewed when rain shows up on the ceiling beside the stack.
Open →Chimney Masonry Repair
Mortar and brick worn by years of heat, rain and old quakes repaired so the stack stays solid and dry.
Open →Chimney Rebuilds
A cracked, leaning or quake-loosened stack taken down and laid up again, with a new crown, cap and flashing.
Open →Fireplace Cleaning
Ash, soot and tar cleared from the firebox, glass and smoke shelf so the hearth looks right and draws well.
Open →Gas Fireplace Cleaning
Yearly service for gas logs, inserts and stoves: burner, pilot, glass and vent cleaned, then a CO reading.
Open →Gas Fireplace Repair
Flickering pilots, cold burners and silent remotes: a meter finds which part has failed.
Open →Fireplace Remodel
Surround, hearth and mantel reworked around a woodstove, insert or open firebox, keeping heat clearances intact.
Open →Fireplace Inserts
Wood, pellet or gas inserts set into an existing firebox and vented up a new liner, so the hearth warms the room.
Open →Pellet Stove Repair
Augers that jam, igniters that stay cold and blowers that quit on pellet stoves and inserts, found and fixed.
Open →Wood Stove Repair
Leaky door seals, sagging baffles, cracked glass and burnt air tubes on woodstoves replaced so a fire lasts overnight.
Open →Gas Logs
Vented gas log sets fitted to an old wood hearth, with the gas line, valve and damper stop done properly.
Open →Chimney Seismic Retrofit
Brick stacks braced or rebuilt lighter so a strong shake is less likely to drop brick through the roof.
Open →Chimney Crown Repair
The cement top of a brick chimney sealed or recast before cracks let rain soak the stack and firebox.
Open →Dryer Vent Cleaning
Lint packed in the dryer duct cleared from the outside hood back to the machine, so loads dry and heat gets out.
Open →Chimney Leak Repair
Rain turning up beside the stack or in the firebox traced to where it actually enters, then stopped there.
Open →Chimney Waterproofing
A breathable masonry repellent brushed onto repaired brick, so storms stay out while trapped damp can still escape.
Open →Chimney Damper Repair
Rusted, warped or jammed dampers freed, rebuilt or replaced, including top-mounted dampers worked by a cable.
Open →Chimney Chase Cover
Rusted lids on wood-framed chimneys replaced with heavier stainless made to fit, so water stops reaching the framing.
Open →