Brick colonial house with chimneys at each end
Covington Chimney Services

Pellet Stove Repair That Gets Your Heat Back

Is This the Job You Need?

Stove and Flue Checked Together
Repair Figures in Writing
Parts Matched to the Model
Notes After Every Visit
Working From Thousand Oaks
Stove and Flue Checked Together
Repair Figures in Writing
Parts Matched to the Model
Notes After Every Visit
Working From Thousand Oaks

What the Crew Does

Pellet stoves stop for a reason, and the display usually hints at it. A clinkered burn pot, a vent packed with ash, a worn igniter, a vacuum switch that trips or a feed motor that has given up will all shut the stove down. We read the code, test the part it points at, clean the burn pot, exhaust path and vent run, and swap the failed piece. Pellets that leave heavy ash come up too.

Error code read and the named part tested
Clinker knocked out of the burn pot
Exhaust path and vent run cleaned of ash
Igniter, feed motor and blowers checked under power
Vacuum and proof-of-fire switches tested
Pellet quality and ash load talked over

Why Pellet Stoves Stop Mid-Winter

People choose pellets for steady heat with little fuss: fill it, set it, forget it until tomorrow. That works until the stove decides otherwise, and it usually decides on the coldest night of the month. In our experience most pellet stove failures come down to three causes. The first is ash. Pellets burn almost completely, but the little that is left gathers in places the owner's weekly clean does not reach, and once the airways choke, the stove runs short of air, burns dirty and shuts itself down. The second is the fuel. Pellets that took on moisture in a damp garage swell and crumble into sawdust, and bags with a lot of fines pack the feed and leave clinker in the fire pot. The third is wear. A pellet stove has motors, fans, a feed screw, an igniter and safety switches, all working hard every day, and each of them eventually tires out.

So the symptoms vary. A stove that hums and clicks but never makes a flame often has a burned-out igniter or a fire pot so caked that the igniter cannot reach the pellets. One that lights and then shuts down after a few minutes usually has a safety switch that is sensing too little draft, because the vent or the exhaust path is choked. A stove that runs but makes a lazy, dark flame and black glass is starved of air or burning wet fuel. A feed that stops while the hopper is full points to a jam or a feed motor at the end of its life. A loud grinding or squealing fan is easy to diagnose. If you can read the stove's display, any error code it shows is useful too. We trace the fault, replace the part that has failed with one made for the stove, and then make sure the stove is clean enough not to fail again next week.

Cleaning, Fuel and Keeping It Running

Every repair visit includes a proper clean, because a repaired stove full of ash is only waiting to fail again. We open the stove up beyond what the owner's manual asks of you each week: the passages behind the firebox walls, the exhaust blower housing, the vent pipe from the stove to the outside, and the cap where it exits. Pellet vents need this more than people expect. The exhaust is pushed out by a fan, so a vent clogged with fine ash leaks under pressure at its joints instead of drawing smoke away the way a wood chimney would. We check those joints and replace any gaskets or seals that have failed. Most stoves that get a full clean once a year, plus the routine emptying of the fire pot and ash pan by the owner, run through a winter without trouble. Stoves that burn every day from November to March may need a second clean mid-season.

Fuel is the part owners control. Store bags off a concrete floor and away from a damp wall, and if a bag feels soft or full of dust when you pour it, keep it for the shoulder season rather than a cold snap. Different brands of pellets burn differently in the same stove, so if your stove has started acting up since you changed brands, tell us; that is useful to know. Pellet stoves and pellet inserts are serviced the same way, and we work on freestanding units and inserts in fireplaces alike. To book, use the contact page with the brand of the stove if you know it and a sentence on what it is doing. Households that heat mostly with pellets usually set their yearly clean for late summer, so the stove is ready before the first chilly night arrives.

How Covington Chimney Services Works a Job

Fault Found First

We trace the problem before any part is ordered

Burners Know Burners

Woodstoves, pellet units and open hearths are our daily work

Price on Paper

You see the figure in writing before work starts

Test Fire Together

After a stove fix, the first fire is built while you watch

Other Jobs We Take On

Chimney Sweep

Creosote scraped and brushed off the flue walls, bagged and hauled off, before the woodpile comes indoors.

Open →

Chimney Inspection

An NFPA 211 Level 1 or Level 2 look at the stove, flue, crown and cap, with findings written in plain order.

Open →

Chimney Repair

Cracked crowns, open joints and loose brick above a working stove put right before they let water or heat through.

Open →

Fireplace Inspection

Open hearth, firebox walls, damper and hearth extension looked over before the season's first log goes in.

Open →

Fireplace Repair

Cracked firebrick, crumbling joints and a sticking damper fixed so the open hearth burns safely again.

Open →

Chimney Level 2 Inspection

A recorded camera pass through the full flue plus attic and crawl space checks, for sales, stove swaps or after a flue fire.

Open →

Chimney Cap Installation

A steel cap with a tight spark screen, stopping rain, birds and the embers a hard-burning stove throws off.

Open →

Chimney Flashing Repair

Metal at the roof-to-chimney joint resealed or renewed when rain shows up on the ceiling beside the stack.

Open →

Chimney Masonry Repair

Mortar and brick worn by years of heat, rain and old quakes repaired so the stack stays solid and dry.

Open →

Chimney Rebuilds

A cracked, leaning or quake-loosened stack taken down and laid up again, with a new crown, cap and flashing.

Open →

Fireplace Cleaning

Ash, soot and tar cleared from the firebox, glass and smoke shelf so the hearth looks right and draws well.

Open →

Gas Fireplace Cleaning

Yearly service for gas logs, inserts and stoves: burner, pilot, glass and vent cleaned, then a CO reading.

Open →

Gas Fireplace Repair

Flickering pilots, cold burners and silent remotes: a meter finds which part has failed.

Open →

Fireplace Remodel

Surround, hearth and mantel reworked around a woodstove, insert or open firebox, keeping heat clearances intact.

Open →

Fireplace Inserts

Wood, pellet or gas inserts set into an existing firebox and vented up a new liner, so the hearth warms the room.

Open →

Wood Stove Repair

Leaky door seals, sagging baffles, cracked glass and burnt air tubes on woodstoves replaced so a fire lasts overnight.

Open →

Gas Logs

Vented gas log sets fitted to an old wood hearth, with the gas line, valve and damper stop done properly.

Open →

Chimney Seismic Retrofit

Brick stacks braced or rebuilt lighter so a strong shake is less likely to drop brick through the roof.

Open →

Chimney Crown Repair

The cement top of a brick chimney sealed or recast before cracks let rain soak the stack and firebox.

Open →

Dryer Vent Cleaning

Lint packed in the dryer duct cleared from the outside hood back to the machine, so loads dry and heat gets out.

Open →

Chimney Liner Installation

Stainless liners run inside an old or cracked flue so a woodstove, insert or pellet unit vents properly.

Open →

Chimney Leak Repair

Rain turning up beside the stack or in the firebox traced to where it actually enters, then stopped there.

Open →

Chimney Waterproofing

A breathable masonry repellent brushed onto repaired brick, so storms stay out while trapped damp can still escape.

Open →

Chimney Damper Repair

Rusted, warped or jammed dampers freed, rebuilt or replaced, including top-mounted dampers worked by a cable.

Open →

Chimney Chase Cover

Rusted lids on wood-framed chimneys replaced with heavier stainless made to fit, so water stops reaching the framing.

Open →

Woodpile reading from Covington Chimney Services

Call (805) 254-2086